We scan the top radiology sources so you don’t have to.
From AI breakthroughs to imaging trends, we serve up real-time radiology insights.
-
End of Life VS. End of Service: A Comprehensive Guide | Block Imaging
“End of Life”. “End of Service”. Sounds intimidating right?
-
Best Pre-owned Mammos in 2025
After 25+ years in the imaging space, we’ve had a front row seat to the “who’s who” of mammography systems.
-
Screen Won't Boot Past 5 Arrows? Try This!
If your system is stuck and fails to boot past the “Five Arrows” screen, there’s a high chance the culprit is something surprisingly simple: the coin cell battery on your SBC (Single Board Computer). Luckily, this is an easy and inexpensive fix. Here’s how to get your system up and running again.
-
The 5 Most Common OEC 9800 & 9900 Issues—and How to Fix Them
Whether you’re on hospital staff or an engineer just unfamiliar with OEC C-arms, these five service calls are the most common issues we help people troubleshoot. Hopefully this quick guide saves you time, reduces system downtime, and keeps things moving for your patients or customers. So without further ado, here are the five most common issues we gets calls about – and stay tuned to see some honorable mentions!
-
Experiencing Communication Failure on a C-arm? Try This!
Getting a Communication Failure Error is a common C-arm issue, but there’s a fairly easy fix. We’ll guide you through the most common cause and solution. As always, if this doesn’t work, reach out to us – we’d love to give you a hand.
-
Pre-Charge Voltage Error on a C-Arm? 3 Common Reasons Why!
Getting a pre-charge voltage error right away on your OEC C-arm definitely throws a wrench into your plans for the day. But luckily for you, we’ve got a troubleshooting guide that will guide you through the three issues it could be and ways to fix each one.
-
4 Most Common O-Arm Problems Solved
Nothing is more frustrating that having to pause your imaging workflow to find a solution to an equipment issue. We’ve compiled the fixes for the four most common problems that you run into when working with Medtronic O-arms to help you get these systems back up and running in no time.
-
Best Portable X-ray Machines in 2025
With the new year comes new demand for portable X-ray systems! We’ve put together a list of the best portable X-ray machines we’ve been seeing on the market.
-
How to Replace a Touchscreen on an OEC 9800
In this guide, we’ll walk you through replacing the touch screen assembly on an OEC 9800.